BioWrap 102

Sustainable Composite Pipe Repair Technology: Lowering Environmental Impact without Compromising Performance

EcoWrap 102, an environmentally friendly composite wrap pipe repair system, applied to a pipe

BioWrap 102: Pushing Pipe Repairs to a greener future

BioWrap 102 is at the forefront of sustainable composite technology. It utilises a two-component epoxy "bio" resin system that, once mixed, has a plant-based chemical content of ~27%.

The performance of our BioWrap 102 composite system is not at all compromised. It uses the same chemicals as "normal" epoxy resins, except the chemicals are derived from plant-based sources rather than petrochemical sources.

BioWrap 102 combines our high performance bio-resin with a glass fibre quad axial fabric. This consists of four layers positioned in four different orientations, 0°/90°/+45°/-45°. This ensures that no matter the geometry of the pipework the fibres in our BioWrap 102 composite system are closely aligned to the hoop direction for maximum pressure retention.

Book A Repair Now

Currently being test to ISO 24817 & ASME PCC-2

Qualified Composite Repair Systems

At Icarus Composites, we make sure to test our Composite Materials to the most stringent industrial standards ensuring we deliver the highest quality composite pipe and tank repairs possible.

Our Composite Systems are qualified to both ISO 24817 & ASME PCC-2 to make sure they meet the requirements of both international standards.

Learn more

Applications: A sustainable composite with all the benefit of equivalent systems

BioWrap 102 is a wet layup epoxy composite repair system. This highly specialised composite repair system is specifically designed for pipe, tank and structural repairs for Heavy Industry. The composite pipe repair system is being rigorously tested to both ISO 24817 & ASME PCC-2 standards.

Book A Repair Now

Technical Data

Download the Technical Data Sheet in the link below

BioWrap 102 TDS

Properties

Data - Metric (Imperial)

Glass transition temperature (Tg)
102°C (215°F)
Composite ply thickness
0.924mm (0.036")
Coefficient of thermal expansion (Circumferential)
2.53 x 10^-5 mm/mm/°C (14.1 in/in/°F)
Coefficient of thermal expansion (Axial)
2.53 x 10^-5 mm/mm/°C (14.1 in/in/°F)
Circumferential young's modulus (Ec)
16,402 MPa (2,378,909 psi)
Axial young's modulus (Ea)
21,136 MPa (3,065,518 psi)
Combined young's modulus
18,619 MPa (2,700,457 psi)
Shear modulus
4,690 MPa (680,227 psi)
Poisson's ration (Circ. - Ax.)
0.22
Poisson's ration (Ax. - Circ.)
0.35
Toughness parameter
113.4 J/m² (0.0540 ft-lb/in²)
Lap shear strength
9.6 MPa (1,392 psi)
Circumferential tensile strength
371.8 MPa (53,925 psi)
Axial tensile strength
194.18 MPa (28,163 psi)
Test temperature
20°C (68°F)